The Draeger X-am 7000 Gas Detector is the solution for the simultaneous and continuous measurement of up to five gases. It is the ideal companion in a variety of applications where the reliable detection of oxygen, toxic and combustible gases and vapors are necessary. The Draeger X-am 7000 is available in two configurations: the rugged five gas unit and the Petro/Chem Dual Infra-Red unit.
It comes standard with an integral pump, which allows sampling through up to 45m of tubing, and data logging of up to 3000 sets of values which can be downloaded to a PC.
The Draeger X-am 7000 can be fitted with three electrochemical, and two catalytic bead, infrared or photo ionization sensors. During operation, it is also possible with the catalytic-Ex sensor to change the gas being measuring or the measurement range of the sensor. In this way, the instrument can be easily adapted to various applications. Draeger sensors are notorious for their fast response time, minor cross sensitivities, high level of accuracy and long lifetimes.
All sensors are pre-calibrated, and therefore a reconfiguration of the Draeger X-am 7000 can be completed by simply changing the sensor meaning that no additional service or maintenance is necessary thus saving any additional costs for the user.
The large graphic display and the auto-zoom function during alarms guarantee an easy recognition of the
measurement values and symbols displayed for immediate reaction to the situation or hazards. All information is
provided in plain text for easy understanding.
Features
5 Gas - FLAM / O2/ H2S / CO / IR CO2
Poison resistant Ex-sensor
Integrated pump
Easy detection of leakages
Built for longevity
Alarm: Visual (360°) and audible (multi-tone >90 dB at 30cm
Display: Clearly structured, scratch resistant display with information in plain text
Ingress Protection: IP67 - complete protection dust and water tight for 30 minutes at depths of up to 1m
Protective rubber boot - protects the instrument against damage from a drop of 1.5m
Size: 150 x 140 x 75 mm
Weight: 1kg including battery pack
Battery Life: 20 hours
Operating Temperature: -20 to +55 °C, short-term -40 to +60 °C
Approvals: ATEX II 2G Ex d ia IIC T4 Gb I M2 Ex d ia I Mb BVS 03 ATEX E 371 X Measurement performance certificate according to: EN 50271:2001 EN 60079-29-1 (for the CatEx sensors from methane to nonane and infrared sensors) EN 45544-1 + 2 (CO, H2S, CO2) EN 50101 (O2)
Package Includes
X-am 7000 unit
3ah battery with charger and power supply
Operation and maintenance manual